Core Technical Parameters:
- Applicable Models: YAP-NJB-600, YAP-NJB-900
- Rated Power: YAP-NJB-600: 600 kW; YAP-NJB-900: 900 kW
- Rated Voltage: 600V
- Rated Current: YAP-NJB-600 (51 Hz): 728 A; YAP-NJB-600 (63.2 Hz): 718 A; YAP-NJB-900: 1,094 A
- Rated Frequency: YAP-NJB-600: 51 Hz, 63.2 Hz; YAP-NJB-900: 10.8 Hz
- Rated Speed: YAP-NJB-600: 505 r/min, 628 r/min; YAP-NJB-900: 105 r/min
- Rated Torque: YAP-NJB-600: 11,346 N·m, 9,124 N·m; YAP-NJB-900: 81,857 N·m
- Pole Configuration: 12 poles
- Duty Type: S1 continuous duty
- Insulation Class: Class H
- Main Unit Protection Class: IP44
- Terminal Box Protection Class: IP55
- Cooling Method: IC06
- Fan Motor Parameters: YAP-NJB-600: 3 kW 380V 50 Hz, 11 kW 380V 50 Hz; YAP-NJB-900: 2×5.5 kW 380V 50 Hz
- Explosion-Proof Rating: Compliant with Category II Zone 2 explosion-proof standards
- Operating Altitude: ≤ 1,500 m
- Operating Temperature: –25 °C to +55 °C (power derating required when ambient temperature exceeds 40 °C)
- Relative Humidity: ≤ 90% (at ambient temperature +20 °C)
Product Features:
- Ultra-large low-speed starting torque, perfectly compatible with mud pump and drawworks heavy-load starting and deep-well pulling operation requirements.
- Direct-drive structure simplifies the transmission system, reducing mechanical failures and substantially improving equipment operational stability.
- Precise and controllable variable frequency speed regulation, with smooth impact-free start-stop, compatible with drilling process fine operation requirements.
- Dedicated dust-proof, sand-proof, and extreme high/low temperature design, withstanding oilfield remote extreme climate environments.
- Strong overload and impact resistance, capable of withstanding drilling stall and sudden load changes without tripping.
Application Scenarios:
Land oil drilling rig mud pumps, drilling drawworks, and heavy-load pulling operation core equipment.
Note: The above are default parameters. Please contact the company for other special requirements.



港口皮带机电机-300x300.png)