TAW Increased-Safety Brushless Synchronous Motor: Zone 2 Applications & Selection Guide

Industrial motors operating in hazardous areas must satisfy two requirements: provide reliable mechanical power and comply with the explosion-protection requirements of the installation site.

The TAW Series Increased-Safety Brushless Synchronous Motor, offered by Smart IJ, is designed for large industrial drive applications where stable synchronous speed, power factor control, and hazardous-area suitability are important.

For petrochemical plants, chemical processing facilities, and other industries with Zone 2 gas-hazardous locations, selecting the correct motor requires more than comparing rated power and voltage. Engineers must also evaluate explosion-protection markings, operating conditions, starting characteristics, and system integration.

This guide explains the TAW Series’ main technical features and the key considerations for selecting an increased-safety synchronous motor.

What Is a TAW Increased-Safety Brushless Synchronous Motor?

The TAW Series is a large three-phase synchronous motor family combining increased-safety design with brushless excitation technology.

It is intended for applications requiring high-power mechanical drives and stable operating speed. Configurations for Zone 2 hazardous gas environments must be evaluated against the site’s applicable explosion-protection requirements.

Its principal technical characteristics include:

  • Increased-safety design: Intended to reduce potential ignition hazards through appropriate electrical and mechanical construction.
  • Brushless excitation: Supplies rotor excitation without conventional brushes and slip rings used for field-current transfer.
  • Synchronous-speed operation: Maintains a speed determined by supply frequency and pole count while the motor remains synchronized.
  • Power factor control: Excitation adjustment can support reactive power management and improved system power factor, within the motor’s operating limits.
  • Large-equipment drive capability: Suitable for evaluation in heavy industrial drive systems requiring consistent operating performance.

These characteristics make the TAW Series relevant to engineers comparing synchronous motor technologies for hazardous industrial environments.

Why Increased-Safety Motor Design Matters in Zone 2 Areas

A Zone 2 hazardous area is a location where an explosive gas atmosphere is not expected during normal operation and, if it occurs, is expected to exist only for a short period.

Even with a lower expected occurrence of explosive gas compared with Zone 1, electrical equipment must be selected according to the site’s hazardous-area classification.

Increased-safety protection is addressed by IEC 60079-7, which establishes requirements for electrical equipment intended for explosive gas atmospheres.

Under this framework:

  • Ex eb represents an increased-safety protection level associated with EPL Gb.
  • Ex ec represents an increased-safety protection level associated with EPL Gc and Zone 2 applications.
  • Equipment suitability also depends on gas group, temperature class, ambient conditions, and the exact certified configuration.

The classification of a hazardous area does not automatically establish that any particular motor is suitable for installation.

For a TAW motor project, the exact Ex marking, applicable certificates, and installation requirements must be verified before procurement.

Key Technical Advantages of the TAW Series

1. Brushless Excitation for Industrial Drive Reliability

Conventional brushed synchronous motor excitation systems use sliding electrical contacts to transfer field current to the rotor.

A brushless excitation system eliminates the conventional field-current brush and slip-ring arrangement, reducing associated wear and routine maintenance requirements.

For large industrial motors, this can provide practical advantages:

  • Fewer brush-related maintenance tasks
  • Reduced reliance on sliding electrical contacts
  • Suitability for continuous industrial operating schedules
  • Improved maintenance planning in facilities with limited shutdown opportunities

Brushless excitation does not eliminate all maintenance requirements. Bearings, cooling arrangements, insulation systems, and excitation components still require appropriate inspection.

2. Power Factor Control and Reactive Power Management

One important advantage of synchronous motor technology is its ability to adjust reactive power behavior through excitation control.

Depending on excitation settings and operating limits, a synchronous motor may operate at a lagging, unity, or leading power factor.

This capability can help industrial facilities manage reactive power demand.

For example, a processing plant operating several large induction motors may have substantial reactive power requirements. A properly engineered synchronous motor installation can potentially contribute to overall power factor management.

However, the achievable power factor and reactive power contribution must be confirmed from the specific motor’s excitation capability, operating point, and technical data.

3. Constant Synchronous Speed for Process Stability

The TAW Series uses synchronous motor technology, with salient-pole construction identified as one of its principal design characteristics.

For a synchronous motor connected to a fixed-frequency power supply, operating speed is determined by supply frequency and the number of poles.

While the motor remains synchronized, normal load variations do not produce the slip characteristic of an induction motor.

This is valuable in applications where consistent speed is necessary for predictable process operation.

However, motor torque capacity, excitation limits, and system stability must still be considered. Excessive loading or abnormal operating conditions can cause loss of synchronism.

4. Engineering Integration for Large Industrial Equipment

Motor performance must be evaluated as part of the entire drive system rather than as an isolated component.

For a large TAW synchronous motor installation, engineering teams should examine:

  • Driven-equipment torque and inertia
  • Starting method and acceleration requirements
  • Excitation and protection systems
  • Power supply capacity and voltage characteristics
  • Cooling and ventilation requirements
  • Mounting dimensions and shaft interfaces
  • Site-specific hazardous-area requirements

Proper integration helps ensure that the selected motor can operate within its specified mechanical, electrical, and thermal limits.

Typical Industrial Applications

TAW increased-safety brushless synchronous motors can be considered for large equipment drive applications in industries where explosive gas atmospheres may be present.

IndustryPotential Drive ApplicationsMain Selection Considerations
Petrochemical processingCompressors, pumps, and auxiliary processing equipmentGas classification, temperature class, duty cycle
Chemical and fertilizer plantsLarge compressors and process machineryStarting performance, operational stability, hazardous-area protection
Oil and gas facilitiesSelected high-power rotating equipmentExplosion-protection certification, environmental suitability
Industrial gas processingCompressors and associated rotating equipmentLoad characteristics, excitation system, continuous operation
Heavy industrial processingLarge fixed-speed equipment where applicableVoltage, torque, cooling, and site classification

Important: Suitability depends on the specific motor configuration and hazardous-area assessment. Zone 2 gas suitability does not automatically establish approval for Zone 1, combustible-dust areas, or underground coal mines.

Increased-Safety vs. Flameproof Motors: What Is the Difference?

Increased-safety motors and flameproof motors use different explosion-protection concepts.

ComparisonIncreased-Safety MotorFlameproof Motor
Protection principleReduces the likelihood of ignition through appropriate equipment designUses a certified enclosure to contain an internal explosion and prevent flame propagation
Common protection markingsEx eb / Ex ecEx db
Hazardous-area suitabilityDepends on protection level and certificationDepends on marking and certification
Engineering considerationsTemperature control, electrical clearances, construction and ignition preventionEnclosure integrity, flamepaths, temperature limits and mechanical construction

Neither protection concept should be assumed superior for every application.

The appropriate solution depends on the area classification, applicable standards, equipment characteristics, and project requirements.

How to Select a TAW Motor for a Zone 2 Project

Before purchasing a large increased-safety synchronous motor, procurement teams and engineering contractors should prepare a clear technical specification.

Step 1: Verify Hazardous-Area Requirements

Confirm the site’s:

  • Hazardous-area zone
  • Gas group
  • Required equipment protection level (EPL)
  • Temperature class
  • Ambient temperature range
  • Applicable national or regional certification requirements

Request documentation demonstrating that the proposed motor configuration matches these conditions.

Step 2: Confirm Electrical Requirements

Provide the required:

  • Rated motor output (kW)
  • Supply voltage (kV or V)
  • Supply frequency (Hz)
  • Required operating speed (rpm)
  • Duty cycle
  • Starting and excitation requirements

These factors determine whether the proposed motor is electrically suitable for the installation.

Step 3: Evaluate Mechanical and Environmental Conditions

Review the driven-equipment characteristics, including load torque, inertia, shaft coupling, and installation orientation.

Environmental considerations may include high humidity, corrosion exposure, high altitude, elevated ambient temperature, or unusual cooling requirements.

Any adaptation must be assessed against the motor’s approved design and applicable certification.

Step 4: Review Documentation and Testing

Before final approval, request the relevant technical documents, which may include:

  • Motor datasheet and dimensional drawing
  • Applicable explosion-protection certificates
  • Ex marking and nameplate information
  • Excitation and starting-system details
  • Inspection and testing documentation
  • Installation, operation, and maintenance instructions

The exact documentation package should be agreed upon during technical evaluation.

TAW Series Motor Solutions from Smart IJ

Smart IJ is the industrial motor brand of Shenzhen Smart IJ Technology Co., Ltd., based in Shenzhen, China.

The company’s motor portfolio covers high-voltage motors, explosion-proof motors, synchronous motors, and special-purpose industrial drive solutions.

For TAW Series procurement, Smart IJ can assist customers with technical requirement review, motor configuration discussions, and coordination of project-specific documentation.

Its broader industrial motor solutions support applications in petrochemical processing, mining, metallurgy, energy, and industrial infrastructure.

Buyers evaluating a TAW Series motor should request the applicable model-specific technical parameters, explosion-protection documentation, and commercial quotation before final equipment selection.

For additional information, visit the Smart IJ industrial motor website or review the company’s industrial motor procurement FAQ.

Frequently Asked Questions About TAW Motors

Is a TAW increased-safety synchronous motor suitable for Zone 2?

The TAW Series is positioned for large industrial drive applications that may require Zone 2 gas-hazardous-area suitability. However, installation is permitted only when the exact motor configuration has the appropriate explosion-protection marking, documentation, and approval for the site requirements.

What is the advantage of brushless excitation?

Brushless excitation removes the conventional brushes and slip rings used for rotor field-current transfer. This can reduce brush-related wear and maintenance, making the technology attractive for large industrial synchronous motor installations.

Can a TAW synchronous motor improve power factor?

Potentially, yes. By controlling rotor excitation within the motor’s capability limits, a synchronous motor can influence its reactive power behavior and may contribute to plant power factor management. Actual performance must be verified for the selected configuration.

Is increased safety the same as flameproof protection?

No. Increased-safety and flameproof motors use different explosion-protection methods. IEC 60079-7 covers increased-safety protection, while IEC 60079-1 addresses flameproof enclosures. Engineers must select equipment according to the specific hazardous-area requirements.

What information is required for a TAW motor quotation?

A useful inquiry should include rated power, voltage, frequency, operating speed, driven-equipment details, hazardous-area classification, gas group, temperature class, operating environment, destination country, and required documentation or certification.

Conclusion: Selecting a TAW Motor for Hazardous Industrial Applications

The TAW Series Increased-Safety Brushless Synchronous Motor combines synchronous-speed operation, brushless excitation, and power factor control capabilities for large industrial drive applications.

For Zone 2 projects, its suitability must be assessed together with the exact explosion-protection marking, operating conditions, system integration requirements, and applicable certification.

Working from a complete engineering specification allows buyers to evaluate performance, safety, and procurement requirements before committing to equipment selection.

Request a TAW Series Technical Consultation

Are you evaluating a high-voltage synchronous motor for a petrochemical facility, chemical plant, or other hazardous industrial installation?

Contact Smart IJ — Shenzhen Smart IJ Technology Co., Ltd. to discuss your project requirements.

Business Email: zhou@ijsmart-tech.com

Website: https://ijsmart-tech.com/

Include your motor specifications and hazardous-area requirements to support an accurate technical evaluation and quotation.

Leave a Comment